Message
|
Cause
|
Corrective Action
|
Address mark not found |
Faulty diskette/tape drive subsystem or hard-disk drive
subsystem (defective system board) |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Alert! Unbuffered and registered DIMMs cannot be mixed |
Combination of unbuffered and registered DIMMs installed |
Replace one or more DIMMs so that all DIMMs are the same type.
See Installing DIMMs and Removing
DIMMs. |
Auxiliary device failure |
Mouse cable connector loose or improperly connected, defective
mouse |
Check the mouse cable connection. If the problem persists,
replace the mouse. |
Attachment failed to respond |
Diskette drive or hard-disk drive controller cannot send data to
associated drive |
Replace the drive's interface cable. |
Bad error-correction code(ECC) on disk read
Controller has failed |
Faulty diskette/tape drive subsystem or hard-disk drive
subsystem (defective system board) |
Replace the system board. See Getting Help for instructions on obtaining technical
assistance. |
Data error |
Faulty diskette, diskette drive, or hard-disk drive |
Replace the diskette, diskette drive, or hard-disk drive. |
Decreasing available
memory |
One or more DIMMs improperly seated or faulty |
Remove and reseat the DIMMs. See Adding Memory . If the problem
persists, replace the DIMMs. |
Diskette drive 0 seek failure
Diskette drive 1 seek failure |
Faulty or improperly inserted diskette, incorrect
configuration settings in System Setup program, loose diskette/tape drive interface cable,
or loose power cable |
Replace the diskette. Run the System Setup program to correct
the diskette drive type. See Chapter 4, "Using the System Setup Program," in the
Dell PowerEdge 2300 Systems User's Guide for instructions. Check the diskette/tape
drive interface cable and power cable connections to the drive. |
Diskette read failure
|
Faulty diskette, faulty or improperly connected diskette/tape
drive interface cable, or loose power cable |
Check the diskette/tape drive interface cable and power cable
connections to the drive. See Installing
Drives in the External Bays. Replace the diskette drive interface cable. |
Diskette subsystem reset failed |
Faulty diskette/tape drive controller (defective system board) |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Diskette write
protected |
Diskette write-protect feature activated |
Move the write-protect tab on the diskette. |
Drive not ready
|
Diskette missing from or improperly inserted in diskette drive |
Reinsert or replace the diskette. |
Embedded server management error
Embedded server
management is not present |
Embedded server management memory may be temporarily corrupted |
Shut down the system to clear the memory, and then restart the
system. If the problem persists, see Getting Help for instructions on obtaining technical assistance. |
Gate A20 failure |
Faulty keyboard controller (defective system board) |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
General failure |
Operating system corrupted or not installed properly |
Reinstall the operating system. |
Hard disk controller
failure
Hard disk drive read failure
Hard disk failure |
Incorrect configuration settings in System Setup program,
improperly connected hard-disk drive, faulty hard-disk drive controller subsystem
(defective system board), or loose power cable |
Check the hard-disk drive configuration settings in the System
Setup program. See Chapter 4, "Using the System Setup Program," in the Dell PowerEdge
2300 Systems User's Guide for instructions. Reinstall the hard-disk drive. Check the
interface cable and power cable connections to the backplane board. See Installing Hard-Disk Drives. |
Invalid configuration information - please run SETUP program |
Incorrect ISA_CLR jumper configuration, incorrect configuration
settings in System Setup program, or faulty battery |
Remove the plug from the ISA_CLR jumper. See Jumpers and Switches for instructions.
Check the System Setup configuration settings. See Chapter 4, "Using the System Setup
Program," in the Dell PowerEdge 2300 Systems User's Guide for instructions.
Replace the battery. See Installing
System Board Options. |
Invalid CPU speed detected - check jumpers |
Incorrect microprocessor jumper configuration |
Check the microprocessor speed jumper. See Jumpers and Switches. |
Invalid NVRAM configuration, resource reallocated |
System detected and corrected a resource conflict when system
resources were allocated using the Resource Configuration Utility |
No action is required. |
I/O parity interrupt at address |
Expansion card improperly installed or faulty |
Reinstall the expansion cards (see Installing System Board Options). If the problem
persists, replace the expansion card. |
Keyboard clock line failure
Keyboard failure |
Keyboard cable connector loose or improperly connected,
defective keyboard, or defective keyboard/mouse controller (defective system board) |
Check the keyboard cable connection. Replace the keyboard. If
the problem persists, replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Keyboard controller
failure |
Defective keyboard/mouse controller (defective system board) |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Keyboard data line failure
Keyboard stuck key failure |
Keyboard cable connector loose or improperly connected,
defective keyboard, or defective keyboard/mouse controller (defective system board) |
Check the keyboard cable connection. Replace the keyboard. If
the problem persists, replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Memory address line failure at address, read value expecting
value
Memory double word logic failure at
address, read value expecting value
Memory odd/even logic failure at address, read value expecting value
Memory write/read failure at address, read value expecting value |
Faulty or improperly seated DIMMs or defective system board |
Remove and reseat the DIMMs. If the problem persists, replace
the DIMMs. See Installing DIMMs
and Removing DIMMs. |
Memory allocation error |
Faulty application |
Restart the application. |
Memory parity interrupt at address |
Improperly seated or faulty DIMMs |
Remove and reseat the DIMMs. If the problem persists, replace
the DIMMs. See Installing DIMMs
and Removing DIMMs. |
Memory tests terminated by keystroke |
POST memory test terminated by pressing <Spacebar> |
No action is required. |
No boot device available |
Faulty diskette, diskette/tape drive subsystem, hard-disk drive,
hard-disk drive subsystem, or no boot disk in drive A |
Replace the diskette or hard-disk drive. If the problem
persists, replace the system board. See Getting Help for instructions on obtaining technical assistance. |
No boot sector on hard-disk drive |
Incorrect configuration settings in System Setup program, or no
operating system on hard-disk drive |
Check the hard-disk drive configuration settings in the System
Setup program. See Chapter 4, "Using the System Setup Program," in the Dell PowerEdge
2300 Systems User's Guide for instructions. |
No timer tick interrupt |
Defective system board |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Non-system disk or disk error |
Faulty diskette, diskette/tape drive subsystem, or hard-disk
drive subsystem |
Replace the diskette or hard-disk drive. If the problem
persists, replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Not a boot diskette |
No operating system on diskette |
Use a bootable diskette. |
Processor or terminator card not installed! |
No microprocessor or terminator card installed in secondary
micro-processor connector |
Install a terminator card or microprocessor in the secondary
microprocessor connector. See Installing
System Board Options for instructions. |
Read fault
Requested sector not found |
Faulty diskette, diskette/tape drive subsystem, or hard-disk
drive subsystem (defective system board) |
Replace the diskette or hard-disk drive. If the problem
persists, replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Reset failed |
Improperly connected diskette/tape drive, hard-disk drive, or
power cable |
Check the diskette/tape drive interface cable and power cable
connections to the diskette drive. See Installing Drives in the External Bays. Replace the diskette drive
interface cable. Reinstall the hard-disk drive. Check the interface cable and power cable
connections to the backplane board. See Installing Hard-Disk Drives. |
ROM bad checksum = address |
Expansion card improperly installed or faulty |
Reinstall the expansion cards (see Installing System Board Options). If the problem
persists, replace the expansion card. |
Sector not found |
Defective sectors on diskette or hard-disk drive |
Replace the diskette or hard-disk drive. |
Seek error |
Defective sectors on diskette or hard-disk drive |
Replace the diskette or hard-disk drive. |
Seek operation failed |
Faulty diskette or hard-disk drive |
Replace the diskette or hard-disk drive. |
Shutdown failure |
Defective system board. |
Replace the battery. See Installing System Board Options. |
Time-of-day clock stopped |
Defective battery or faulty chip (defective system board) |
Replace the battery. See Installing System Board Options. If the problem persists, replace
the system board. See Getting Help
for instructions on obtaining technical assistance. |
Time-of-day not set |
Incorrect Time or Date settings or defective system battery |
Check the Time and Date settings. See Chapter 4, "Using the
System Setup Program," in the Dell PowerEdge 2300 Systems User's Guide for
instructions. If the problem persists, replace the battery as instructed in Installing System Board Options. |
Timer chip counter 2 failed |
Defective system board |
Replace the system board. See Getting Help for instructions on obtaining technical assistance. |
Unexpected interrupt in protected mode |
Improperly seated DIMMs or faulty keyboard/mouse controller chip
(defective system board) |
Remove and reseat the DIMMs. If the problem persists, replace
the DIMMs. See Installing DIMMs
and "Removing DIMMs" in Chapter 8. If the problem still persists, replace the
system board. See Getting Help
for instructions on obtaining technical assistance. |
Unsupported CPU detected in SLOT n |
Microprocessor not supported by system |
Install a correct version of the microprocessor in the specified
microprocessor connector. See Installing
System Board Options for instructions. |
Unsupported CPU speed in CMOS |
Microprocessor not supported by BIOS |
Upgrade the BIOS. See Chapter 2, "Using the System Setup
Program," in the Dell PowerEdge 2300 Systems User's Guide for instructions. |
Write fault
Write fault on selected drive |
Faulty diskette or hard-disk drive |
Replace the diskette or hard-disk drive. |
NOTE: For the full name of an abbreviation or acronym used in this table,
see the Abbreviations and Acronyms list. |