Indicators, Codes, and Messages: Dell PowerEdge 2650 Systems Service Manual

Back to Contents Page

Indicators, Codes, and Messages

Dell™ PowerEdge™ 2650 Systems Service Manual

  System-Status Indicators

  System Identification Indicators

  Front-Panel Indicators and Features

  Back-Panel Indicators and Features

  Power Indicator Codes

  Hard-Drive Indicator Codes

  NIC Indicator Codes

  Cooling Fan Indicator Codes

  LCD Status Messages

  System Messages

  System Beep Codes

  Warning Messages

  Diagnostics Messages

  Alert Messages



The system indicators and features are illustrated in this section. This section also describes each type of message, and lists the possible causes and actions you can take to resolve any problems indicated by a message.


System-Status Indicators

The system's bezel has an indictor that can represent system status when the bezel is installed (see Figure 3-1). The indicator signifies when the system is operating properly or when the system needs attention. The back-panel indicator functions the same as the bezel indicator. The back-panel indicator connector allows an indicator to be attached that will also function the same as the bezel indicator (see Figure 3-3).

A caution code signifies a problem with microprocessors, power supply, system or power-supply fans, system temperature, hard drives, system memory, expansion cards, or integrated SCSI controller.

Table 3-1 lists the system's status indicator codes.

Figure 3-1. System-Status Indicators

Table 3-1. System-Status Indicator Codes 

Bezel Indicators

Back-Panel Indicators

Indicator Code

Status

Caution

Off

Off

Off

No power is available to the system, or the system is not powered on.

On

Off

Blue

The system is operating normally.

Off

Blinking

Amber blinking

The system has detected an error and requires attention.

Blinking

Off

Blue blinking

The system is identifying itself (see "System Identification Indicators").


System Identification Indicators

The identification buttons on the front and back panels can be used to identify a particular system within a rack. See Figure 3-2 to locate the front-panel system identification button. See Figure 3-3 to locate the back-panel system identification button and indicator.

When either of the identification buttons is pushed, the identification indicator on the back blinks until one of the buttons is pushed again. If the bezel is installed, the system status indicator will also blink. If an indicator is connected to the back-panel system status indicator connector, that indicator will also blink.

Systems management software can also be used to cause the status and identification indicators to blink to identify a particular system. For more information, see the systems management software documentation.


Front-Panel Indicators and Features

Additional indicators are located behind the bezel. The front-panel status LCD provides information using an alphanumeric character display (see "LCD Status Messages"). See Figure 3-2 for the front-panel indicators and features.

Figure 3-2 shows the front-panel features of the system. Table 3-2 describes the front-panel features.

Figure 3-2. Front-Panel Features

Table 3-2. Front-Panel Features 

Component

Description

Power button

Turns system power off and on.

  • If you turn off the system using the power button and the system is running an ACPI-compliant operating system (such as Microsoft® Windows® 2000), the system can perform an orderly shutdown before power is turned off.
  • If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed.

The button is enabled in the System Setup program. When disabled, the button can only turn system power on. For more information, see your User's Guide and the operating system's documentation.

Power indicator

Provides information on power status (see "Power Indicator Codes").

CD and diskette drive indicators

Indicates read or write access to the respective drive.

hard-drive indicators

Provide information on the status of the respective hard drive (see "Hard-Drive Indicator Codes").

NIC indicators

Indicate whether the NIC has a valid link to the network (see "NIC Indicator Codes").

Status LCD

Can signify when the system is operating correctly or when the system needs attention (see "LCD Status Messages").

System identification button

Can be used to identify a particular system (see "System Identification Indicators").

NMI button

Can be used to troubleshoot software and device driver errors when using certain operating systems. This button is often referred to as a "force dump switch" and can be pressed using the end of a paper clip. When the option is enabled in the System Setup program and the button is pressed, an NMI alerts the system.

Use this button only if directed to do so by qualified support personnel or by the operating system's documentation. For more information, see your User's Guide and the operating system's documentation.

Bezel connector

Transmits logic signals for the system-status indicator on the bezel (see "System-Status Indicators").

I/O ports and connectors

Attach peripheral devices to the system. For more information, see "I/O Ports and Connectors" in your User's Guide.


Back-Panel Indicators and Features

Figure 3-3 shows the back-panel features of the system. Table 3-3 describes the back-panel features.

Figure 3-3. Back-Panel Features

Table 3-3. Back-Panel Features 

Component

Description

Power supply indicators

Provides information on power status (see "Power Indicator Codes").

NIC indicators

Provides information on NIC status (see "NIC Indicator Codes").

System status indicator connector

Connects to an indicator that can signify when the system is operating correctly or when the system needs attention (see "System-Status Indicators").

System identification indicator

Signifies when the system is operating correctly or when the system needs attention, and can identify a particular system (see "System Identification Indicators").

System identification button

Can be used to identify a particular system (see "System Identification Indicators").

Expansion slots

The expansion cards are installed on the system's riser board (see Figure 5-4 to identify the expansion slots).

I/O ports and connectors

Attach peripheral devices to the system. For more information, see "I/O Ports and Connectors" in your User's Guide.

Embedded remote access Ethernet connector

Used for remote system administration. For more information, see your systems management documentation.

Power connectors and grounding post

Connects the system's power supplies to a power source (see "Power Supplies").


Power Indicator Codes

The system has indicators on the front panel and the power supplies that signify system power status.

Power-Button Indicator Codes

The power button controls the power input to the system's power supplies. The power button indicator can provide information on power status (see Figure 3-2).

Table 3-4 lists the power button indicator codes.

Table 3-4. Power-Button Indicator Codes 

Indicator

Indicator Code

On

Indicates that power is supplied to the system, and the system is operational.

Off

Indicates that no power is supplied to the system.

Blinking

Indicates that power is supplied to the system, but the system is in a standby state. For more information on standby states, see your operating system documentation.

Power-Supply Indicator Codes

Each hot-pluggable AC or DC power supply has indicators that can provide information on power status, fault, and the presence of power (see Figure 3-4). Table 3-5 lists the power-supply indicator codes.

Figure 3-4. Power-Supply Indicators

Table 3-5. Power-Supply Indicator Codes 

Indicator

Indicator Code

Power-on

Green indicates that the power supply is operational.

Fault

Red indicates a problem with the power supply (fan failure, voltage error, etc.).

Power present

Green indicates that power is present at the power supply and that the system is connected to a power source.


Hard-Drive Indicator Codes

Each hard-drive carrier has two indicators: a busy indicator and a status indicator (see Figure 3-5). The indicators provide information on the status of the respective hard drive. Table 3-6 lists the drive indicator codes.

Figure 3-5. Hard-Drive Indicators

Table 3-6 lists the drive indicator codes. Different codes display as drive events occur in the system. For example, in the event of a hard-drive failure, the "drive failed" code appears. After the drive is selected for removal, the "preparing for removal" code appears. After the replacement drive is installed, the "preparing for operation, drive online" code appears.

Table 3-6. Hard-Drive Indicator Codes 

Indicator

Indicator Code

Drive bay empty, ready for insertion or removal

Off

Drive being prepared for operation, drive online

Steady green

Drive being identified

Blinks green four times per second

Drive being prepared for removal

Blinks green twice per second at equal intervals

Drive rebuilding

Blinks green twice per second at unequal intervals

Drive failed

Blinks amber four times per second

Predicted failure for the drive

Blinks green, then amber, and then off, repeating this sequence every two seconds

NOTE: The "drive busy" indicator signifies whether the hard drive is active on the SCSI bus. This indicator is controlled by the hard drive.


NIC Indicator Codes

Each NIC on the back panel has an indicator that provides information on network activity and link status (see Figure 3-6). Table 3-7 lists the NIC indicator codes on the back panel.

The front panel has a link indicator for each NIC (see Figure 3-2). Each indicator signifies whether the corresponding NIC is connected to a valid link partner on the network.

Figure 3-6. NIC Indicators

Table 3-7. NIC Indicator Codes 

Indicator

Indicator Code

Link and activity indicators are off

The NIC is not connected to the network.

Link indicator is green

The NIC is connected to a valid link partner on the network.

Activity indicator is amber blinking

Network data is being sent or received.


Cooling Fan Indicator Codes

Each individual fan has a status indicator on the system board adjacent to the respective fan's connector (see Figure 3-7). To locate the fan connectors on the system board, see Figure 5-3. Table 3-8 lists the fan indicator codes.

Figure 3-7. Cooling Fan Indicators

Table 3-8. Cooling Fan Indicator Codes 

Indicator

Indicator Code

Off

The fan is not required.

Green

The fan is functioning properly.

Amber blinking

The fan is malfunctioning.


LCD Status Messages

The system's bezel indictor can signify when the system is operating correctly or when the system needs attention (see Figure 3-1). When the bezel indicator signifies an error condition, remove the bezel to see further information provided by the status LCD.

The LCD can display two lines of alphanumeric characters. The display codes are presented in two color combinations:

  • White characters on a blue background — Information only; no action is required.

  • Amber characters on a black background — The system needs attention.

Table 3-9 lists the LCD status messages that can occur and the probable cause for each message. The LCD messages refer to events recorded in the SEL. For information on the SEL and configuring system management settings, see the systems management software documentation.

Table 3-9. LCD Status Messages 

Line 1
Message

Line 2
Message

Causes

Corrective Actions

SYSTEM ID

SYSTEM NAME

SYSTEM ID is a unique name, five characters or less, defined by the user.

SYSTEM NAME is a unique name, 16 characters or less, defined by the user.

The system ID and name display under the following conditions:

  • The system is powered on.
  • The power is off and active POST errors are displayed.

This message is for information only.

You can change the system ID and name in the System Setup program (see "Using the System Setup Program").

E0000

OVRFLW CHECK LOG

LCD overflow message.

A maximum of three error messages can display sequentially on the LCD. The fourth message displays as the standard overflow message.

Check the SEL for details on the events.

E0119

TEMP AMBIENT

Ambient system temperature is out of acceptable range.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans").

E0119

TEMP BP

Backplane board is out of acceptable temperature range.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, replace the backplane board (see "SCSI Backplane Board").

E0119

TEMP CPU n

Specified microprocessor is out of acceptable temperature range.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, ensure that the specified microprocessor's heat sink is properly installed. If the problem persists, replace the faulty microprocessor (see "Microprocessors").

E0119

TEMP SYSTEM

System board is out of acceptable temperature range.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, replace the system board (see "System Board").

E0212

VOLT 3.3

System power supply is out of acceptable voltage range; faulty or improperly installed power supply.

Ensure that the power supplies are properly installed. If the problem persists, replace the faulty power supply(s) (see "Power Supplies").

E0212

VOLT 5

E0212

VOLT 12

E0212

VOLT BATT

Faulty battery; faulty system board.

Ensure that the system battery is properly installed. If the problem persists, replace the battery (see "System Battery"). If the problem persists, replace the system board (see "System Board").

E0212

VOLT BP 12

Backplane board is out of acceptable voltage range.

Ensure that the power cables are securely connected to the backplane board (see "SCSI Backplane Board"). Ensure that the power supplies are properly installed. If the problem persists, replace the faulty power supply(s) (see "Power Supplies").

E0212

VOLT BP 3.3

E0212

VOLT BP 5

E0212

VOLT CPU VRM

Microprocessor VRM voltage is out of acceptable range; faulty or improperly installed microprocessor VRM; faulty system board.

Ensure that supported VRMs of the same type are properly installed. If the problem persists, replace the VRMs (see Figure 4-29). If the problem persists, replace the system board (see "System Board").

E0212

VOLT NIC 1.8V

Integrated NIC voltage is out of acceptable range; faulty or improperly installed power supply; faulty system board.

Ensure that the power supplies are properly installed. If the problem persists, replace the faulty power supply(s) (see "Power Supplies"). If the problem persists, replace the system board (see "System Board").

E0212

VOLT NIC 2.5V

E0212

VOLT PLANAR REG

System board is out of acceptable voltage range; faulty or improperly installed system board.

E0276

CPU VRM n

Specified microprocessor VRM is faulty, unsupported, improperly installed, or missing.

Ensure that supported VRMs of the same type are properly installed. If the problem persists, replace the VRM (see Figure 4-29).

E0276

MISMATCH VRM n

E0280

MISSING VRM n

E0319

PCI OVER CURRENT

Faulty or improperly installed expansion card.

Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards").

E0412

RPM FAN n

Specified cooling fan is faulty, improperly installed, or missing.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans").

E0780

MISSING CPU n

Microprocessor is not installed in the specified socket.

A microprocessor must be installed in socket 1, and a VRM must be installed for each installed microprocessor. Install a microprocessor in the specified socket or remove the VRM for the specified microprocessor if that microprocessor is not installed (see "Microprocessors"). To identify the microprocessors and VRMs, see Figure 5-3.

E07F0

CPU IERR

Faulty or improperly installed microprocessor.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors").

E07F1

TEMP CPU n HOT

Specified microprocessor is out of acceptable temperature range and has halted operation.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, ensure that the microprocessor heat sinks are properly installed. If the problem persists, replace the faulty microprocessor (see "Microprocessors").

E07F4

POST CACHE

Faulty or improperly installed microprocessor.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors").

E07F4

POST CPU REG

E07F4

POST CPU SMI

SMI handler failed to initialize; faulty system board.

Replace the system board (see "System Board").

E07FA

TEMP CPU n THERM

Specified microprocessor is out of acceptable temperature range and is operating at a reduced speed, or frequency.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, ensure that the microprocessor heat sinks are properly installed. If the problem persists, replace the faulty microprocessor (see "Microprocessors").

E0876

POWER PS n

No power available from the specified power supply; specified power supply is improperly installed or faulty.

Ensure that the power supplies are properly installed. If the problem persists, replace the faulty power supply(s) (see "Power Supplies").

E0880

INSUFFICIENT PS

Insufficient power is being supplied to the system; power supplies are improperly installed, faulty, or missing.

E0CB2

MEM SPARE BANK

Correctable errors threshold was met in a memory bank: errors were remapped to the spare bank.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0CF1

MBE DIMM Bank n

Memory modules installed in the specified bank are not the same type and size; faulty memory module(s).

Ensure that all banks contain memory modules of the same type and size and that they are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of main memory.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0CF1

POST NO MEMORY

Main-memory refresh verification failure.

Ensure that all banks contain memory modules of the same type and size and that they are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0CF5

LOG DISABLE SBE

Multiple single-bit errors on a single memory module.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0D76

DRIVE FAIL

Faulty or improperly installed hard drive or RAID controller.

Ensure that the hard drives are properly installed. If the problem persists, replace the faulty hard drive(s) (see "Hard Drives"). If the problem persists, replace the RAID controller (see "Integrated RAID Controller" and "RAID Controller Card").

E0F04

POST CMOS

CMOS write/read failure; faulty system board.

Replace the system board (see "System Board").

E0F04

POST CPU SPEED

Microprocessor speed control sequence failure.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors").

E0F04

POST DMA INIT

DMA initialization failure; DMA page register write/read failure.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0F04

POST DMA REG

Faulty system board.

Replace the system board (see "System Board").

E0F04

POST KYB CNTRL

Faulty keyboard controller; faulty system board.

Replace the system board (see "System Board").

E0F04

POST MEM RFSH

Main-memory refresh verification failure.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0F04

POST PIC REG

Master or slave PIC register test failure.

Replace the system board (see "System Board").

E0F04

POST SHADOW

BIOS-shadowing failure.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

E0F04

POST SHD TEST

Shutdown test failure.

E0F04

POST SIO

Super I/O chip failure; faulty system board.

Replace the system board (see "System Board").

E0F04

POST TIMER

Programmable interval timer test failure; faulty system board.

Replace the system board (see "System Board").

E0F0B

POST ROM CHKSUM

Faulty or improperly installed expansion card.

Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards").

E0F0C

VID MATCH CPU n

Specified microprocessor is faulty, unsupported, improperly installed, or missing.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors").

E10F3

LOG DISABLE BIOS

BIOS disabled logging errors.

Check the SEL for details on the errors.

E13F2

IO CHANNEL CHECK

Faulty or improperly installed expansion card; faulty system board.

Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards"). If the problem persists, replace the system board (see "System Board").

E13F4

PCI PARITY

E13F5

PCI SYSTEM

E13F8

CPU BUS INIT

Faulty or improperly installed microprocessor or system board.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists, replace the system board (see "System Board").

E13F8

CPU BUS PARITY

Faulty system board.

Replace the system board (see "System Board").

E13F8

CPU MCKERR

Machine check error; faulty or improperly installed microprocessor; faulty system board.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists, replace the system board (see "System Board").

E13F8

HOST BUS

Faulty system board.

Replace the system board (see "System Board").

E13F8

HOST TO PCI BUS

E13F8

MEM CONTROLLER

Faulty or improperly installed memory module; faulty system board.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules"). If the problem persists, replace the system board (see "System Board").

E1580

POWER CONTROL

Faulty system board.

Replace the system board (see "System Board").

E20F1

OS HANG

Operating system watchdog timer timed out.

Restart your system. If the problem persists, see your operating system documentation.

EFFF0

RAC ERROR

Remote access controller firmware failure; faulty system board.

Replace the expansion-card riser board (see "Expansion-Card Riser Board").

EFFF1

POST ERROR

BIOS error.

Update the BIOS firmware. Download the latest firmware from the Dell | Support website at support.dell.com.

EFFF2

BP ERROR

Faulty or improperly installed backplane board.

Ensure that the interface cables are securely connected to the SCSI backplane board. If the problem persists, replace the backplane board (see "SCSI Backplane Board").

Solving Problems Described by LCD Status Messages

When a single message appears on the status LCD, locate the code in Table 3-9 and perform the suggested corrective action. The code on the LCD can often specify a very precise fault condition that is easily corrected. For example, if the code E0280  MISSING VRM 2 appears, you know that a microprocessor is installed in socket 2, but the VRM for that microprocessor is either improperly installed or missing.

In contrast, you might be able to determine the problem if multiple related errors occur. For example, if you receive a series of messages indicating multiple voltage faults, you might determine that the problem is a failing power supply.

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a normal state. For example, if temperature for a component goes out of range, the LCD displays the fault; when the temperature returns to the acceptable range, the message is removed from the LCD. For other faults, you must take action to remove the message from the display:

  • Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.

  • Chassis intrusion — When you remove the cover, the system assumes that you are servicing the bad component; the LCD clears when you replace the cover.

  • Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately ten seconds, reconnect the power cable, and restart the system.

Any of these actions will remove fault messages, and return the status indicators and LCD colors to the normal state. Messages will reappear under the following conditions:

  • The sensor returns to a normal state but fails again, resulting in a new SEL entry.

  • The system is reset and new error events are detected.

  • A failure is recorded from another source that maps to the same display entry.


System Messages

System messages appear on the console during POST to notify you of a possible problem with the system. If you are performing console redirection, system messages will appear on the remote console. Table 3-10 lists the system messages that can occur and the probable cause for each message.

NOTE: If you receive a system message that is not listed in Table 3-10, check the documentation for the application program that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

Table 3-10. System Messages 

Message

Causes

Corrective Actions

Address mark not found

Faulty CD/diskette drive subsystem or hard-drive subsystem; faulty system board.

Replace the faulty drive(s) (see "CD and Diskettes Drives" and "Hard Drives"). If the problem persists, replace the system board (see "System Board").

Alert! Current configuration does not support redundant memory. Redundant memory is disabled.

Memory modules installed are not the same type and size in all banks; faulty memory module(s).

Ensure that all banks contain memory modules of the same type and size and that they are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

Alert! Unsupported memory or incomplete sets in the following bank(s): Bank n

Memory modules installed in the specified bank are not the same type and size; faulty memory module(s).

Amount of available memory limited to 256 MB!

OS Install Mode is enabled in the System Setup program.

Disable OS Install Mode in the System Setup program (see "Using the System Setup Program").

Auxiliary device failure

Loose or improperly connected mouse or keyboard cable; faulty mouse or keyboard.

Check the mouse and keyboard cables and connectors. If the problem persists, replace the mouse and keyboard. If the problem persists, replace the system board (see "System Board").

BIOS Update Attempt Failed!

Remote BIOS update attempt failed.

Retry the BIOS update. Download the latest firmware from the Dell | Support website at support.dell.com.

CD-ROM drive not found

Improperly connected or missing CD drive.

Ensure that the CD drive is properly installed. If the problem persists, replace the CD drive (see "CD and Diskettes Drives").

CPUs with different cache sizes detected

Microprocessors with different cache sizes are installed.

Ensure that all microprocessors have the same cache size and that they are properly installed (see "Microprocessors").

Decreasing available memory

Faulty or improperly installed memory modules.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

Diskette drive n seek failure

Incorrect configuration settings in the System Setup program.

Run the System Setup program to correct the settings (see "Using the System Setup Program").

Faulty or improperly installed diskette drive.

Ensure that the diskette drive is properly installed. If the problem persists, replace the diskette drive (see "CD and Diskettes Drives").

Diskette read failure

Faulty or improperly inserted diskette.

Replace the diskette.

Diskette subsystem reset failed

Faulty or improperly installed diskette drive.

Ensure that the diskette drive is properly installed. If the problem persists, replace the diskette drive (see "CD and Diskettes Drives").

ECC memory error

Faulty or improperly installed memory modules.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

Error: Maximum PCI option ROM count exceeded!

Too many expansion cards have ROM enabled in the System Setup program.

Disable ROM for some of the expansion cards (see "Using the System Setup Program").

Gate A20 failure

Faulty keyboard controller; faulty system board.

Replace the system board (see "System Board").

Hard disk controller failure

Incorrect configuration settings in System Setup program; improperly installed hard drive, or loose interface or power cable; faulty hard-drive controller subsystem.

Run the System Setup program to correct the drive type (see "Using the System Setup Program"). If the problem persists, ensure that the hard drives are properly installed (see "Hard Drives"). If the problem persists, replace the system board (see "System Board").

Hard disk read failure

I/O parity interrupt at address

Faulty or improperly installed expansion card.

Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards").

Invalid configuration information - please run SETUP program

Incorrect configuration settings in System Setup program; NVRAM_CLR jumper is installed; faulty system battery.

Check the System Setup configuration settings (see "Using the System Setup Program"). Remove the NVRAM_CLR jumper (see Figure 5-2 for jumper location). If the problem persists, replace the system battery (see "System Battery").

Invalid NVRAM configuration, resource re-allocated

System configuration data has been ignored.

Check the System Setup configuration settings (see "Using the System Setup Program").

Invalid SCSI configuration

SCSI cable detected on connector SCSIB of the SCSI backplane, daughter card not present

A SCSI cable is connected to the channel B connector on the SCSI backplane board; SCSI backplane daughter card is not installed.

If a cable is connected to the SCSIB backplane board connector, the SCSI backplane daughter card must be installed. Ensure that the backplane daughter card is properly installed (see "SCSI Backplane Daughter Card").

Keyboard controller failure

Faulty keyboard controller; faulty system board.

Replace the system board (see "System Board").

Keyboard clock line failure

Loose or improperly connected keyboard cable; faulty keyboard; faulty keyboard controller.

Check the keyboard cable and connector. If the problem persists, replace the keyboard. If the problem persists, replace the system board (see "System Board").

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Memory address line failure at address, read value expecting value

Faulty or improperly installed memory modules.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

Memory double word logic failure at address, read value expecting value

Memory high address line failure at start address to end address

Memory high data line failure at start address to end address

Memory odd/even logic failure at start address to end address

Memory parity failure at start address to end address

Memory parity error at address

Memory write/read failure at address, read value expecting value

No boot device available

Faulty or missing CD/diskette drive subsystem, hard drive, or hard-drive subsystem.

Check the configuration settings in the System Setup program for Integrated Devices (see "Using the System Setup Program"). If booting from a SCSI controller, ensure that the controller is properly connected. If the problem persists, replace the faulty drive(s) (see "CD and Diskettes Drives" and "Hard Drives"). If the problem persists, replace the system board (see "System Board").

No boot sector on hard- disk

No operating system on hard drive.

Check the hard-drive configuration settings in the System Setup program (see "Using the System Setup Program").

No PXE-capable device available

<F12> pressed during POST and no PXE devices are detected.

Check the configuration settings in the System Setup program for the NICs (see "Using the System Setup Program").

No timer tick interrupt

Faulty system board.

Replace the system board (see "System Board").

Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion card(s); faulty or improperly installed expansion card.

Ensure that cables to expansion cards are properly connected. Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards").

Plug & Play Configuration Error Embedded xxx

Error encountered in initializing PCI device; faulty system board.

Install the NVRAM_CLR jumper and reboot the system (see Figure 5-2 for jumper location). If the problem persists, ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards"). If the problem persists, update the BIOS firmware. Download the latest firmware from the Dell | Support website at support.dell.com.

Plug & Play Configuration Error PCI_n

Error encountered in initializing PCI adapter.

Primary backplane is not present

Faulty or improperly installed SCSI backplane board.

Ensure that the SCSI backplane board is properly installed. If the problem persists, replace the backplane board (see "SCSI Backplane Board").

Processor n internal error

Faulty microprocessor; faulty system board.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists, replace the system board (see "System Board").

Processor bus parity error

Processor in socket 1 not installed!

No microprocessor installed in primary microprocessor socket.

Install a microprocessor in the primary microprocessor socket. Also, ensure that a VRM for processor 1 is installed (see "Microprocessors").

Remote access controller error

Embedded remote access memory may be temporarily corrupted.

To clear the embedded remote access memory, shut down the system, disconnect the power cords, wait approximately 30 seconds, reconnect the power cords, and restart the system. If the problem persists, ensure that the expansion-card riser board is properly installed. If the problem persists, replace the expansion-card riser board (see "Expansion-Card Riser Board"). If the problem persists, replace the system board (see "System Board").

Remote access controller is not present

SCSI cable not present on connector A or B of the primary backplane

SCSI cable is loose, improperly connected, or faulty.

Ensure that the SCSI cables are properly installed. If problem persists, add or replace the cables.

Shutdown failure

Shutdown test failure.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

System backplane error

Faulty or improperly installed SCSI backplane board.

Ensure that the SCSI backplane board is properly installed. If the problem persists, replace the backplane board (see "SCSI Backplane Board").

System halted! Must power down

Wrong password entered too many times.

Information only.

Time-of-day clock stopped

Faulty battery.

Ensure that the system battery is properly installed. If the problem persists, replace the battery (see "System Battery").

Time-of-day not set - please run SETUP program

Incorrect Time or Date settings; faulty system battery.

Check the Time and Date settings (see "Using the System Setup Program"). If the problem persists, replace the system battery (see "System Battery").

Timer chip counter 2 failed

Faulty system board.

Replace the system board (see "System Board").

Unsupported CPU combination

Microprocessor(s) is not supported by the system.

Update the BIOS firmware. Download the latest firmware from the Dell | Support website at support.dell.com. If the problem persists, install a supported microprocessor combination (see "Microprocessors").

Unsupported CPU stepping detected

Unsupported DIMM detected in the RAID DIMM slot!

RAID memory module is not supported by the system.

Install a correct version of the RAID memory module (see "Integrated RAID Controller").

Unsupported RAID key detected!

RAID hardware key is not supported by the system.

Install the RAID hardware key for your specific system (see "Integrated RAID Controller").

Utility partition not available

The <F10> key was pressed during POST, but no utility partition exists on the boot hard drive.

Create a utility partition on the boot hard drive (see "Using the Dell OpenManage Server Assistant CD" in your User's Guide).

The VRM for the processor in socket n is not installed.

Specified microprocessor VRM is faulty, unsupported, improperly installed, or missing.

A VRM must be installed for each installed microprocessor. Install a VRM for the specified microprocessor or remove the VRM for the specified microprocessor if that microprocessor is not installed (see "Microprocessors"). To identify the microprocessors and VRMs, see Figure 5-3.

Warning: Detected mode change from RAID to SCSI B of the embedded RAID subsystem.

Type of controller has changed since previous system boot.

Back up information on the hard drives before changing the type of controller used with the drives.

Warning: Detected missing RAID hardware for the embedded RAID subsystem. Data loss will occur! Press Y to switch mode to SCSI, press any other key to disable both channels. Press Y to confirm the change; press any other key to cancel.

Warning: Firmware is out- of-date, please update.

Firmware error.

Update the firmware. Download the latest firmware from the Dell | Support website at support.dell.com.

Warning! No microcode update loaded for processor n

BIOS error.

Update the BIOS firmware. Download the latest firmware from the Dell | Support website at support.dell.com.

Warning! System FRU is not programmed

Faulty or corrupt data in NVRAM.

Ensure that the system board is properly installed (see "System Board"). If the problem persists, see "Obtaining Technical Assistance."

Write fault

Faulty diskette, CD/diskette drive assembly, hard drive, or hard-drive subsystem.

Replace the faulty drive(s) (see "CD and Diskettes Drives" and "Hard Drives"). If the problem persists, replace the system board (see "System Board").

Write fault on selected drive


System Beep Codes

When an error that cannot be reported on the monitor occurs during a boot routine, the system may emit a series of beeps that identifies the problem.

When a beep code is emitted, record it on a copy of the Diagnostics Checklist (see "Getting Help" in your Installation and Troubleshooting Guide) and then look it up in Table 3-11. If you are unable to resolve the problem by looking up the meaning of the beep code, use the system diagnostics to identify a more serious cause.

NOTE: If the system boots without a keyboard, mouse, or monitor attached, the system will not issue beep codes related to those peripherals.

Table 3-11. System Beep Codes 

Code

Cause

Corrective Action

1-1-2

CPU register test failure.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors").

1-1-3

CMOS write/read failure; faulty system board.

Replace the system board (see "System Board").

1-1-4

BIOS error.

Update the BIOS firmware. Download the latest firmware from the Dell | Support website at support.dell.com.

1-2-1

Programmable interval-timer failure; faulty system board.

Replace the system board (see "System Board").

1-2-2

DMA initialization failure.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

1-2-3

DMA page register write/read failure.

1-3-1

Main-memory refresh verification failure.

1-3-2

No memory installed.

1-3-3

Chip or data line failure in the first 64 KB of main memory.

1-3-4

Odd/even logic failure in the first 64 KB of main memory.

1-4-1

Address line failure in the first 64 KB of main memory.

1-4-2

Parity failure in the first 64 KB of main memory.

1-4-3

Fail-safe timer test failure.

1-4-4

Software NMI port test failure.

2-1-1 through
2-4-4

Bit failure in the first 64 KB of main memory.

3-1-1

Slave DMA-register failure.

Replace the system board (see "System Board").

3-1-2

Master DMA-register failure.

3-1-3

Master interrupt-mask register failure.

3-1-4

Slave interrupt-mask register failure.

3-2-2

Interrupt vector loading failure.

3-2-4

Keyboard-controller test failure.

Check the keyboard cable and connector. If the problem persists, replace the keyboard. If the problem persists, replace the system board (see "System Board").

3-3-1

CMOS failure.

Replace the system board (see "System Board").

3-3-2

System configuration check failure.

3-3-3

Keyboard controller not detected.

3-3-4

Video memory test failure.

3-4-1

Screen initialization failure.

3-4-2

Screen-retrace test failure.

3-4-3

Video ROM search failure.

4-2-1

No timer tick.

4-2-2

Shutdown test failure.

4-2-3

Gate A20 failure.

4-2-4

Unexpected interrupt in protected mode.

Ensure that the expansion cards are properly installed. If the problem persists, replace the faulty expansion card(s) (see "Expansion Cards").

4-3-1

Improperly installed or faulty memory modules.

Ensure that the memory modules are properly installed. If the problem persists, replace the faulty memory module(s) (see "Memory Modules").

4-3-2

No memory modules installed in bank 1.

Install memory modules in bank 1 of the same type and size (see "Memory Modules").

4-3-3

Faulty system board.

Replace the system board (see "System Board").

4-3-4

Time-of-day clock stopped.

Ensure that the system battery is properly installed. If the problem persists, replace the battery (see "System Battery").

4-4-1

Super I/O chip failure; faulty system board.

Replace the system board (see "System Board").

4-4-2

BIOS-shadowing failure.

Ensure that the system cooling fans are properly installed. If the problem persists, replace the faulty fan(s) (see "System Fans"). If the problem persists, replace the system board (see "System Board").

4-4-3

Microprocessor speed control sequence failure.

Ensure that the microprocessors are properly installed. If the problem persists, replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists, replace the system board (see "System Board").

4-4-4

Cache test failure; faulty microprocessor.


Warning Messages

A warning message alerts you to a possible problem and asks you to take corrective action before the system continues a task. For example, before you format a diskette, a message may warn you that you may lose all data on the diskette. Warning messages usually interrupt the procedure and require you to respond by typing y (yes) or n (no).

NOTE: Warning messages are generated by either the application program or the operating system. See the documentation that accompanied the operating system or application program.

Diagnostics Messages

When you run a test group or subtest in system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist (see "Getting Help" in your Installation and Troubleshooting Guide), and then follow the instructions in that section for obtaining technical assistance.


Alert Messages

The optional systems management software generates alert messages for your system. For example, the software generates messages that appear in the SNMP trap log file. Alert messages consist of information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.


Back to Contents Page

 